2025-11-21 - 2026-11-21
Overview
1 Release published by 1 user
Published
v0.6.0
napalm-netgear-switches 0.6.0
11 Pull requests merged by 1 user
Merged
#23 fix: Plus and Smart reads that read as empty, README requirements (#21, #22)
Merged
#20 docs(readme): describe netgear_plus beside netgear_smart
Merged
#18 fix: Plus stubs, Plus ping, Smart optional_args and message (#9, #5, #7)
Merged
#17 fix: an unknown ARP age is -1.0, not 0.0
Merged
#16 chore: Python 3.12 is the floor (NAPALM/driver-standard#6)
Merged
#15 chore: adopt the NAPALM driver standard
Merged
#13 fix(ssh): verify the host key netOrk expects, report the one seen (NetOrk/netork#1167)
Merged
#12 feat: report the firmware Netgear offers, not a warning (0.4.0)
Merged
#11 feat!: configure_snmp_agent with the caller's values replaces fix_snmp (0.3.0)
Merged
#10 feat: declare the SNMP health OIDs instead of collecting them (0.2.0)
Merged
#4 ci: run the tests and build the package on every push and pull request
11 Issues closed from 1 user
Closed
#21 getters report unsupported or failed reads as empty (Plus MAC/LLDP/config/…, Plus VLAN fetch, Smart get_snmp_config)
Closed
#22 README: the requirements table names NAPALM 4.0 and misses paramiko and netaddr
Closed
#19 README: the getter table describes only netgear_smart; netgear_plus lacks most of it
Closed
#5 netgear_plus: a ping sweep reports every host as an error
Closed
#7 Packaging and small issues: missing dependency, German message, caller's dict mutated
Closed
#9 netgear_plus: set_vlan and set_interface exist only to raise NotImplementedError
Closed
#14 chore: adopt the NAPALM driver standard
Closed
#6 netgear_smart fix_snmp probably times out in config mode
Closed
#3 netgear_smart: get_lldp_neighbors() nutzt ein Kommando, das v7-Firmware nicht kennt
Closed
#2 get_config() liefert die Uptime mit — jeder Vergleich meldet eine Änderung
Closed
#1 get_config() hangs 30s and fails on "v7" CLI switches with long running-config output
12 Issues created by 1 user
Opened
#1 get_config() hangs 30s and fails on "v7" CLI switches with long running-config output
Opened
#2 get_config() liefert die Uptime mit — jeder Vergleich meldet eine Änderung
Opened
#3 netgear_smart: get_lldp_neighbors() nutzt ein Kommando, das v7-Firmware nicht kennt
Opened
#8 Agnostic structure: SNMP profile, fix template, firmware catalogue out
Opened
#5 netgear_plus: a ping sweep reports every host as an error
Opened
#6 netgear_smart fix_snmp probably times out in config mode
Opened
#7 Packaging and small issues: missing dependency, German message, caller's dict mutated
Opened
#9 netgear_plus: set_vlan and set_interface exist only to raise NotImplementedError
Opened
#14 chore: adopt the NAPALM driver standard
Opened
#19 README: the getter table describes only netgear_smart; netgear_plus lacks most of it
Opened
#21 getters report unsupported or failed reads as empty (Plus MAC/LLDP/config/…, Plus VLAN fetch, Smart get_snmp_config)
Opened
#22 README: the requirements table names NAPALM 4.0 and misses paramiko and netaddr