The README introduces both drivers (line 3: "NAPALM community driver for Netgear Smart Managed and Netgear Plus Managed switches"), but its single "Implemented getters" table and the "Tested devices", "Optional arguments" and "CLI notes" sections describe the SSH/CLI netgear_smart driver only. For netgear_plus (HTTP, napalm_netgear/netgear_plus.py) several rows marked ✅ are wrong:
cli, load_merge_candidate, load_replace_candidate, compare_config, commit_config, discard_config, rollback raise NotImplementedError (e.g. line 547: raise NotImplementedError("Config management is not supported for Netgear Plus switches.")).
Netmiko options (port, force_no_enable, canonical_int_fmt) do not apply; Plus logs in with a password only (the username is ignored).
Expected
A column per driver in the getter table (or a separate table for netgear_plus), its own tested models (GS308EP per the module docstring) and its connection notes.
Priority: P4 — documentation only.
Found during the bug sweep of 2026-11-01.
## What happens
The README introduces both drivers (line 3: "NAPALM community driver for **Netgear Smart Managed** and **Netgear Plus Managed** switches"), but its single "Implemented getters" table and the "Tested devices", "Optional arguments" and "CLI notes" sections describe the SSH/CLI `netgear_smart` driver only. For `netgear_plus` (HTTP, `napalm_netgear/netgear_plus.py`) several rows marked ✅ are wrong:
- `cli`, `load_merge_candidate`, `load_replace_candidate`, `compare_config`, `commit_config`, `discard_config`, `rollback` raise `NotImplementedError` (e.g. line 547: `raise NotImplementedError("Config management is not supported for Netgear Plus switches.")`).
- `get_mac_address_table`, `get_arp_table`, `get_users`, `get_snmp_information`, `get_ntp_servers` return empty values.
- Netmiko options (`port`, `force_no_enable`, `canonical_int_fmt`) do not apply; Plus logs in with a password only (the username is ignored).
## Expected
A column per driver in the getter table (or a separate table for `netgear_plus`), its own tested models (GS308EP per the module docstring) and its connection notes.
Priority: P4 — documentation only.
Found during the bug sweep of 2026-11-01.
Blocking a user prevents them from interacting with repositories, such as opening or commenting on pull requests or issues. Learn more about blocking a user.
What happens
The README introduces both drivers (line 3: "NAPALM community driver for Netgear Smart Managed and Netgear Plus Managed switches"), but its single "Implemented getters" table and the "Tested devices", "Optional arguments" and "CLI notes" sections describe the SSH/CLI
netgear_smartdriver only. Fornetgear_plus(HTTP,napalm_netgear/netgear_plus.py) several rows marked ✅ are wrong:cli,load_merge_candidate,load_replace_candidate,compare_config,commit_config,discard_config,rollbackraiseNotImplementedError(e.g. line 547:raise NotImplementedError("Config management is not supported for Netgear Plus switches.")).get_mac_address_table,get_arp_table,get_users,get_snmp_information,get_ntp_serversreturn empty values.port,force_no_enable,canonical_int_fmt) do not apply; Plus logs in with a password only (the username is ignored).Expected
A column per driver in the getter table (or a separate table for
netgear_plus), its own tested models (GS308EP per the module docstring) and its connection notes.Priority: P4 — documentation only.
Found during the bug sweep of 2026-11-01.