fix(facts): read serial number and uptime from the status page #28

Merged
christianmanivong merged 1 commits from fix/facts-from-status-page into main 2026-11-12 16:22:03 +00:00
1 Commits
Author SHA1 Message Date
Christian Manivong 1fda222d56 fix(facts): read serial number and uptime from the status page
driver / lint (pull_request) Successful in 20s
driver / standard (pull_request) Successful in 20s
driver / types (pull_request) Successful in 1m8s
driver / test (3.13) (pull_request) Successful in 58s
driver / test (3.12) (pull_request) Successful in 1m6s
driver / lowest (pull_request) Successful in 26s
driver / build (pull_request) Successful in 36s
driver / security (pull_request) Successful in 1m5s
CI / driver (pull_request) Successful in 2m23s
driver / publish (pull_request) Skipped
get_facts read SerialNumber and SystemUpTime from getBasicInformation,
which a VMG4005-B50A does not send, and reported "" and 0. The gateway
has both in DeviceInfo of the DAL's cardpage_status, the answer the
interfaces are read from. get_facts now reads that answer once and takes
the interfaces, serial number and uptime from it. Model and firmware stay
with getBasicInformation, which does carry them.

Closes #27