Priority: P3 (important, not urgent): netOrk shows the gateway without a serial number and without uptime; nothing else reads them wrong (an uptime of 0 counts as unknown, so no restart is detected from it).
get_facts reads serial_number and uptime from getBasicInformation (SerialNumber, SystemUpTime). A VMG4005-B50A (V5.17(ABQA.3.1)C0) sends neither there; its whole answer is result, ModelName, SoftwareVersion, CurrentLanguage, AvailableLanguages, RememberPassword, FWUpgradeProgressST. So a read-only get_facts against it reports serial_number: '' and uptime: 0.
The gateway has both in cardpage_status, which get_interfaces already reads (#23), under Object[0].DeviceInfo:
That is what its status page shows (serial number and an uptime of 156 days 18 h). ModelName and SoftwareVersion are there too.
Found while fixing the host name (#26), which had the same cause.
Priority: P3 (important, not urgent): netOrk shows the gateway without a serial number and without uptime; nothing else reads them wrong (an uptime of 0 counts as unknown, so no restart is detected from it).
`get_facts` reads `serial_number` and `uptime` from `getBasicInformation` (`SerialNumber`, `SystemUpTime`). A VMG4005-B50A (V5.17(ABQA.3.1)C0) sends neither there; its whole answer is `result`, `ModelName`, `SoftwareVersion`, `CurrentLanguage`, `AvailableLanguages`, `RememberPassword`, `FWUpgradeProgressST`. So a read-only `get_facts` against it reports `serial_number: ''` and `uptime: 0`.
The gateway has both in `cardpage_status`, which `get_interfaces` already reads (#23), under `Object[0].DeviceInfo`:
```json
"DeviceInfo": {"ModelName": "VMG4005-B50A", "SerialNumber": "S000Y00000001", "SoftwareVersion": "V5.17(ABQA.3.1)C0", "UpTime": 13544274}
```
That is what its status page shows (serial number and an uptime of 156 days 18 h). `ModelName` and `SoftwareVersion` are there too.
Found while fixing the host name (#26), which had the same cause.
Blocking a user prevents them from interacting with repositories, such as opening or commenting on pull requests or issues. Learn more about blocking a user.
Priority: P3 (important, not urgent): netOrk shows the gateway without a serial number and without uptime; nothing else reads them wrong (an uptime of 0 counts as unknown, so no restart is detected from it).
get_factsreadsserial_numberanduptimefromgetBasicInformation(SerialNumber,SystemUpTime). A VMG4005-B50A (V5.17(ABQA.3.1)C0) sends neither there; its whole answer isresult,ModelName,SoftwareVersion,CurrentLanguage,AvailableLanguages,RememberPassword,FWUpgradeProgressST. So a read-onlyget_factsagainst it reportsserial_number: ''anduptime: 0.The gateway has both in
cardpage_status, whichget_interfacesalready reads (#23), underObject[0].DeviceInfo:That is what its status page shows (serial number and an uptime of 156 days 18 h).
ModelNameandSoftwareVersionare there too.Found while fixing the host name (#26), which had the same cause.