get_facts read SerialNumber and SystemUpTime from getBasicInformation, which a VMG4005-B50A does not send, and reported "" and 0. The gateway has both in DeviceInfo of the DAL's cardpage_status, the answer the interfaces are read from. get_facts now reads that answer once and takes the interfaces, serial number and uptime from it. Model and firmware stay with getBasicInformation, which does carry them. Closes #27