add test case get_facts for sg500-28-K9

see #38 and #37
This commit is contained in:
Daniel Bacher committed 2020-11-05 17:20:44 +01:00
1 parent 394adfbe8f
commit fe2eff45f3
6 files changed
+191

No files matched your search

@@ -0,0 +1,69 @@
{
"fqdn" : "switch1.",
"hostname" : "switch1",
"interface_list" : [
"gi1/1/1",
"gi1/1/2",
"gi1/1/3",
"gi1/1/4",
"gi1/1/5",
"gi1/1/6",
"gi1/1/7",
"gi1/1/8",
"gi1/1/9",
"gi1/1/10",
"gi1/1/11",
"gi1/1/12",
"gi1/1/13",
"gi1/1/14",
"gi1/1/15",
"gi1/1/16",
"gi1/1/17",
"gi1/1/18",
"gi1/1/19",
"gi1/1/20",
"gi1/1/21",
"gi1/1/22",
"gi1/1/23",
"gi1/1/24",
"gi1/1/25",
"gi1/1/26",
"Po1",
"Po2",
"Po3",
"Po4",
"Po5",
"Po6",
"Po7",
"Po8",
"Po9",
"Po10",
"Po11",
"Po12",
"Po13",
"Po14",
"Po15",
"Po16",
"Po17",
"Po18",
"Po19",
"Po20",
"Po21",
"Po22",
"Po23",
"Po24",
"Po25",
"Po26",
"Po27",
"Po28",
"Po29",
"Po30",
"Po31",
"Po32"
],
"model" : "SG500-28",
"os_version" : "1.4.11.5",
"serial_number" : "A1B2C3F4G5",
"uptime" : 1232968,
"vendor" : "Cisco"
}
@@ -0,0 +1,32 @@
Name/address lookup is enabled
Domain Timeout: 2 seconds
Domain Retry: 1 times
Domain Polling Interval: 8 seconds
Default Domain Table
Domain Source Interface Preference
-------------------------------------------- ------- --------- ----------
Domain name is not configured
Name Server Table
IP Address Source Interface Preference
-------------------------------------------- ------- --------- ----------
Name server is not configured
Cache Table
Flags: (STA/DYN, OK/NE/??)
STA - Static, DYN - Dynamic
OK - Okay, NE - Negative Cache, ?? - No Response
Remaining
Host Addresses Type State TTL
------------------------- ------------------------ ---- ------ ----------
No hostname is mapped to an IP address
@@ -0,0 +1,65 @@
Flow Link Back Mdix
Port Type Duplex Speed Neg ctrl State Pressure Mode
-------- ------------ ------ ----- -------- ---- ----------- -------- -------
gi1/1/1 1G-Copper -- -- -- -- Down -- --
gi1/1/2 1G-Copper -- -- -- -- Down -- --
gi1/1/3 1G-Copper Full 1000 Enabled Off Up Disabled Off
gi1/1/4 1G-Copper -- -- -- -- Down -- --
gi1/1/5 1G-Copper -- -- -- -- Down -- --
gi1/1/6 1G-Copper -- -- -- -- Down -- --
gi1/1/7 1G-Copper -- -- -- -- Down -- --
gi1/1/8 1G-Copper -- -- -- -- Down -- --
gi1/1/9 1G-Copper -- -- -- -- Down -- --
gi1/1/10 1G-Copper -- -- -- -- Down -- --
gi1/1/11 1G-Copper -- -- -- -- Down -- --
gi1/1/12 1G-Copper Full 1000 Enabled Off Up Disabled Off
gi1/1/13 1G-Copper -- -- -- -- Down -- --
gi1/1/14 1G-Copper Full 1000 Enabled Off Up Disabled On
gi1/1/15 1G-Copper Full 1000 Enabled Off Up Disabled On
gi1/1/16 1G-Copper -- -- -- -- Down -- --
gi1/1/17 1G-Copper -- -- -- -- Down -- --
gi1/1/18 1G-Copper -- -- -- -- Down -- --
gi1/1/19 1G-Copper -- -- -- -- Down -- --
gi1/1/20 1G-Copper -- -- -- -- Down -- --
gi1/1/21 1G-Copper -- -- -- -- Down -- --
gi1/1/22 1G-Copper -- -- -- -- Down -- --
gi1/1/23 1G-Copper -- -- -- -- Down -- --
gi1/1/24 1G-Copper -- -- -- -- Down -- --
gi1/1/25 1G-Combo-C -- -- -- -- Down -- --
gi1/1/26 1G-Combo-F Full 1000 Disabled Off Up Disabled Off
Flow Link
Ch Type Duplex Speed Neg control State
-------- ------- ------ ----- -------- ------- -----------
Po1 -- -- -- -- -- Not Present
Po2 -- -- -- -- -- Not Present
Po3 -- -- -- -- -- Not Present
Po4 -- -- -- -- -- Not Present
Po5 -- -- -- -- -- Not Present
Po6 -- -- -- -- -- Not Present
Po7 -- -- -- -- -- Not Present
Po8 -- -- -- -- -- Not Present
Po9 -- -- -- -- -- Not Present
Po10 -- -- -- -- -- Not Present
Po11 -- -- -- -- -- Not Present
Po12 -- -- -- -- -- Not Present
Po13 -- -- -- -- -- Not Present
Po14 -- -- -- -- -- Not Present
Po15 -- -- -- -- -- Not Present
Po16 -- -- -- -- -- Not Present
Po17 -- -- -- -- -- Not Present
Po18 -- -- -- -- -- Not Present
Po19 -- -- -- -- -- Not Present
Po20 -- -- -- -- -- Not Present
Po21 -- -- -- -- -- Not Present
Po22 -- -- -- -- -- Not Present
Po23 -- -- -- -- -- Not Present
Po24 -- -- -- -- -- Not Present
Po25 -- -- -- -- -- Not Present
Po26 -- -- -- -- -- Not Present
Po27 -- -- -- -- -- Not Present
Po28 -- -- -- -- -- Not Present
Po29 -- -- -- -- -- Not Present
Po30 -- -- -- -- -- Not Present
Po31 -- -- -- -- -- Not Present
Po32 -- -- -- -- -- Not Present
@@ -0,0 +1,3 @@
NAME: "1" DESCR: "SG500-28 28-Port Gigabit Stackable Managed Switch"
PID: SG500-28-K9 VID: V02 SN: A1B2C3F4G5
@@ -0,0 +1,18 @@
Unit Type
---- ----------------------
1 SG500-28
Unit FAN
Status
---- ---------
1 N/A
Unit Temperature (Celsius) Temperature Sensor Status
---- ------------------------- -------------------------
1 N/A
Unit Up time
---- ---------------
1 00,00:21:27
@@ -0,0 +1,4 @@
Unit SW version Boot version HW version
------------------- ------------------- ------------------- -------------------
1 1.4.11.5 1.3.5.06 V02