# Security
A BMC can power a server off, mount virtual media and open a remote console. Its
credentials are worth as much as root on every machine it manages.
## Credentials
- Use a dedicated BMC account for netOrk, not the factory administrator. A read-only role
(Redfish `ReadOnly`) suffices for everything except power control, which needs
`Operator`.
- netOrk's credential gating applies unchanged: no job without credentials.
- Close Redfish sessions after each poll. BMCs allow few concurrent sessions, and a leaked
session can lock the web UI out.
## IPMI over LAN
- IPMI 2.0's RAKP handshake returns a salted hash of the user's password to any client that
names a valid user, before authentication (CVE-2013-4786). The hash can be cracked
offline. This is part of the protocol, not a bug a firmware update fixes.
- Cipher suite 0 (no authentication) is enabled on some BMCs and allows login with any
password.
- So the `ipmi` entry point is read-only and a fallback only. `get_management_protocols`
reporting `IPMI.ProtocolEnabled = true` should become a finding in netOrk, with the advice
to disable IPMI over LAN where Redfish is available.
## Power control
- `set_power_state` can take a production server down. In netOrk it needs a
`ConfirmDialog`, a permission of its own, and an audit log entry.
- `ForceOff`/`ForceRestart`/`PowerCycle` skip the OS shutdown; offer `GracefulShutdown`/
`GracefulRestart` first.
- `reboot_host` restarts only the BMC (`Manager.Reset`). The managed server keeps running.
## Firmware
BMC firmware versions from `UpdateService/FirmwareInventory` feed netOrk's vulnerability
management. Supermicro BMCs in particular have had serious published vulnerabilities, and
the X10 Redfish firmware line is no longer updated.
## Network placement
A BMC belongs in a management network that only administrators and netOrk can reach. A BMC
reachable from a user or guest VLAN is itself a finding for the segmentation checks.