Christian Manivong 5f8a4ef975 docs: design notes for a Redfish/IPMI BMC driver
No code yet. The README explains why one Redfish driver with vendor quirk
modules beats a Supermicro-only IPMI driver, and keeps IPMI over LAN as a
read-only fallback. docs/ holds a draft for a new ManagementController
role base in napalm-device-types, the getter-to-resource map, the first
test device (Supermicro X10DRL-i, Redfish firmware 3.91), the security
points (IPMI RAKP hash disclosure, power control, credentials) and the
test plan with DMTF mockups and fixtures to record.
2026-10-13 01:15:57 +02:00

3.1 KiB

Getters mapped to Redfish resources

Paths use the usual single-member IDs (Systems/1, Managers/1, Chassis/1); the driver must follow the collections instead of assuming IDs, because vendors differ (Dell uses System.Embedded.1, HPE uses 1, Supermicro uses 1).

Authentication

  • Session: POST /redfish/v1/SessionService/Sessions with user and password returns an X-Auth-Token header and the session's URI. Use the token, DELETE the session on close. BMCs allow few concurrent sessions, so leaking them locks out the web UI.
  • Basic auth works on most services and is the fallback.
  • Self-signed certificates are the norm; verification is configurable per device.

NAPALM getters

Getter Resource Fields
get_facts Systems/{id}, Managers/{id} Manufacturer, Model, SerialNumber, HostName; BMC FirmwareVersion as os_version. uptime is not in Redfish (return -1). interface_list from Managers/{id}/EthernetInterfaces
get_interfaces Managers/{id}/EthernetInterfaces/* BMC ports: MACAddress, SpeedMbps, LinkStatus, InterfaceEnabled
get_interfaces_ip same IPv4Addresses, IPv6Addresses
get_environment Chassis/{id}/Thermal (Temperatures[], Fans[]), Chassis/{id}/Power (PowerSupplies[], PowerControl[].PowerConsumedWatts) Newer services move these to ThermalSubsystem, PowerSubsystem and Sensors; read whichever exists. CPU and memory of the host OS are unknown to a BMC
get_users AccountService/Accounts/* UserName, RoleId, Enabled
get_ntp_servers Managers/{id}/NetworkProtocol NTP.NTPServers (newer schema versions only)
get_snmp_information Managers/{id}/NetworkProtocol SNMP.ProtocolEnabled (details vary)
get_config n/a A BMC has no configuration file. Not implemented

Role methods (draft, see role.md)

Method Resource
get_power_state Systems/{id}: PowerState
set_power_state POST Systems/{id}/Actions/ComputerSystem.Reset with ResetType; allowed values from ResetType@Redfish.AllowableValues (or the ActionInfo resource)
reboot_host (the BMC) POST Managers/{id}/Actions/Manager.Reset
get_hardware_inventory Systems/{id} (ProcessorSummary, MemorySummary), Systems/{id}/Processors/*, Systems/{id}/Memory/*, Systems/{id}/Storage/* (older: SimpleStorage), Chassis/{id}/Power PSUs, Systems/{id}/EthernetInterfaces/*
get_event_log Systems/{id}/LogServices/*/Entries or Managers/{id}/LogServices/*/Entries (where the SEL lives varies by vendor)
get_firmware_inventory UpdateService/FirmwareInventory/*: Name, Version, Updateable
get_management_protocols Managers/{id}/NetworkProtocol: HTTP, HTTPS, SSH, IPMI, SNMP, KVMIP, VirtualMedia, SSDP, each with ProtocolEnabled and Port

IPMI fallback (ipmi entry point)

Read-only, via pyghmi: device ID and FRU data for get_facts, sensor data repository for get_environment, chassis status for get_power_state, SEL for get_event_log. No power control over IPMI.