feat: read-only IPMI driver; report a missing Redfish license (0.2.0)
A Supermicro X10DRL-i refuses Redfish without a license (SUM, DCMS or
OOB), even the service root. IPMI answers without one.
- New entry point `ipmi` (napalm_redfish.ipmi.IpmiDriver) on
ManagementControllerDriver, over pyghmi: facts and inventory from the
FRU (serial number, system UUID), the BMC's LAN interface, sensors
(temperatures, fans, power supplies), the power state, the event log
and the BMC firmware. Read-only: no power control, no BMC reset.
Tested against recordings of the X10 with serials, the UUID, MACs and
IPs replaced.
- RedfishDriver.open() no longer fails on a license refusal: get_facts
returns what is known without Redfish, get_device_warnings reports
bmc_license_required with the licenses the BMC names, every other
getter raises. netOrk then shows the reason instead of an offline BMC.
- IpmiDriver is not exported from the package: NAPALM's own
get_network_driver("redfish") takes the first driver class of
napalm_redfish.
This commit is contained in:
1 parent
bfbeb19255
commit
332e6090a7
17 files changed
+1194
-19
No files matched your search
@@ -4,3 +4,9 @@ without a Supermicro license. Requests were made without credentials.
|
||||
service_root_403.json GET /redfish/v1/ -> HTTP 403, Content-Type application/json
|
||||
landing_page.html GET / -> HTTP 200, the BMC web login page (trimmed to
|
||||
the head and the login form action)
|
||||
|
||||
ipmi/ Read over IPMI 2.0 (pyghmi 1.6, lanplus) with a BMC account, 2026-10-13. One file per
|
||||
pyghmi call: power (get_power), net_configuration (get_net_configuration),
|
||||
firmware (get_firmware), inventory (get_inventory), sensors (get_sensor_data,
|
||||
each SensorReading's attributes), health (get_health), event_log (get_event_log).
|
||||
Serial numbers, the system UUID, MAC addresses and IPs are replaced by placeholders.
|
||||