`show running-config` is preceded by a header block, and one of its lines
reports the system uptime. That value necessarily differs between any two
reads, so every caller comparing consecutive configs sees a change each
time.
Measured on a GS110TPv3 under NetOrk: 876 of 894 stored config snapshots
marked as changed, one git commit and one config_changed warning per poll,
while every other device at the same installation sat between 2 and 18. The
history was worthless for that switch — a genuine change would have been
invisible among hundreds of uptime diffs.
Only the uptime line is removed. Model, firmware version, serial and MAC are
stable and belong in a config backup; a changed firmware version is exactly
the kind of change worth recording.
netgear_plus is unaffected — its get_config() returns empty strings.
The first read after this lands reports one real change, since the line
disappears from the stored config. That is unavoidable and happens once.
get_device_warnings() now returns only {code, meta} — severity, title,
message, and action are resolved centrally by netork's
WARNING_CATALOG (netork/core/device_warnings.py), not by the driver.
Keeps this driver independent of netork and avoids per-vendor drift in
how the same warning code is presented.
"v7" CLI firmware has no "terminal length 0" equivalent (see
_send_paged_command's docstring), so a config long enough to paginate
emits "--More--" prompts that _send_command's expect_string=base_prompt
match never sees. On real hardware (GS110TPv3, 7 VLANs, 10 interfaces)
this hung every scheduled config-backup poll for 30s and failed with
"Pattern not detected: '<prompt>[>#]' in output.", so the config was
never actually backed up. get_mac_address_table()/get_vlans() already
use _send_paged_command() for the same reason on other long outputs;
get_config() now does too.
Also fixed tests/unit/test_driver.py's import/patch target
(napalm_netgear_plus -> napalm_netgear, the actual package name) —
the whole file has been uncollectable since its initial commit, no CI
was wired up here to catch it. And removed a dead unreachable
`return {"success": ..., "output": ...}` line after get_health_metrics's
real return (undefined names, ruff F821), unrelated leftover found
while fixing the above.
_conf_prompt() only matched the legacy "(Config)" prompt, so on v7
"Cisco-like" CLI (lowercase "(config)") _enter_config_mode() blocked for
the full read_timeout - this was the cause of fix_snmp hanging.
_action_fix_snmp() also never returned a result on the legacy path, and
v7 firmware has no snmp-server/show snmp commands at all. It now detects
v7 CLI up front and returns a clear failure message instead of hanging.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
get_poe_status()/set_poe() implement PoE port config via the ProSafe CLI's
'power inline' interface sub-commands. get_interfaces() now enriches chN
LAG entries and their member ports with trunk_group/lag_members/lag_mode
by parsing 'show port-channel all'. New set_lag_members() adds/removes
members via addport/deleteport.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
SNMP health metrics using Netgear enterprise MIB (OID 4526) for
memory free/total and CPU utilization string parsing, plus IF-MIB counters.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
NetgearPlus: get_snmp_config() returns None (SNMP not accessible via HTTP API).
NetgearSmart: get_snmp_config() reads current community, fix_snmp configures
'snmp-server community public ro' via CLI.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>