The checks against line breaks and double quotes made procurve.py 20
lines longer than the quality ratchet allows (1365, recorded 1345). The
module-level ping parser moves to parsers.py, which holds every other
pure CLI parser, as parse_ping_output; its two result dicts become one
helper, so it is no longer over 50 lines. Behaviour is unchanged; tests
for an unreachable target and an unknown answer are added. The baseline
is lowered to what is measured now (procurve.py 1300, the ping entry
gone).
netOrk aligns every device's NTP servers and time zone with its site's
(NetOrk/netork#2360, #2366). A ProCurve keeps them as configuration
lines: sntp server priority <1-3> (or ntp server lines when 16.x runs
timesync ntp), time timezone <minutes> and time daylight-time-rule.
get_time_sync() reads those lines from show running-config, over REST
through the /cli endpoint, and the zone as None: the switch keeps
minutes and a rule, no name. configure_time_sync() writes the servers
in the protocol the switch runs (SNTP unless it runs NTP, switching
TimeP to sntp unicast), keeping those already in place from the first
on; the zone as minutes and the switch's own US/EU rule, or user-defined
dates for other Sunday rules, from the zone's POSIX rule. What the switch
cannot take is refused before anything is sent: more than 3 SNTP or 8
NTP servers, host names, half an hour of summer time, a change on a
weekday. A change is saved with write memory; values already in place
are not sent again, so the alignment on every poll does not churn.
Over REST the writes need the CLI, so the temporary SSH session
configure_snmp_agent opened is now the _config_cli() context manager
both use. get_ntp_servers() reads through get_time_sync() on every
transport; it and get_ntp_stats() move to time_sync.py with the rest of
the clock, so procurve.py shrinks (1383 -> 1339 lines). The unused
parse_ntp_servers() and ProcurveApiClient.get_ntp_servers() are gone.
Over the REST API, cli() returned the /cli endpoint's
result_base64_encoded field as it came: base64 instead of the command's
output. It now decodes it and drops the NUL byte the switch ends it with,
in the same parser the SNMP read over REST uses.
New finding, confirmed by the show snmp-server answer recorded from a
ProCurve switch; no issue filed.
- The six except Exception: pass (REST logout, the extra-ports lookup, the
per-port detail in get_interfaces, closing CLI and REST sessions) now log
at debug level (B110), so a swallowed failure leaves a trace.
- nosec for comparing a reported address with 0.0.0.0 (B104) and for the
empty password field of get_users (B105, now a named constant); both are
false positives.
- A long error message is split into adjacent f-strings; the unused ARP
entry type is named _entry_type.
- tests: the failed-open test expects ConnectionException instead of any
Exception; raise ... from exc.
Mechanical: ruff format, and ruff check --fix with the rule set every NAPALM
driver uses (E, F, I, UP, B at line length 100, Python 3.10). What ruff
cannot fix comes in the next commit.
A 2800-series switch on J.15.09 polled over CLI came back with no
interfaces and an empty OS version, while VLANs and ARP parsed fine.
`show interfaces brief` on that firmware has an Intrusion Alert column
between the `|` and Enabled, and puts Mode before MDI rather than after:
Port Type | Alert Enabled Status Mode Mode ...
3-Trk3 100/1000T | No Yes Down 1000FDx MDI ...
The regex read Alert as Enabled, then failed on Yes where it wanted
Up|Down, so no line matched. It now skips the Alert column where there is
one and takes the speed from either position. Trunk members are listed as
`<port>-Trk<n>`; the port is `<port>` and the suffix becomes its
trunk_group, so the per-port `show interfaces 3` is a command the switch
knows.
The empty OS version was the alternatives list in _send_command. It moved
to the next command on "% Invalid" or "Error", but ProCurve rejects an
unknown command with "Invalid input: system-information" -- so that line
was parsed as system information. "Invalid input" now counts as failure.
Getting there took longer than it should have, because the first symptom
was "Authentication failed: Login failed". That was Telnet's error, the
last transport tried; the REST probe and both SSH attempts had failed
before it and said nothing above debug level. In fact the switch had run
out of CLI sessions and closed SSH straight after the password. open()
now records why each transport failed, and both the auth error and the
final "Cannot connect" carry that list.
Fixtures are that switch's output, with hostname, serial and MAC
replaced.
Closes#2Closes#3Closes#4
Old ProCurve show version starts with "Image stamp:" — the HP product
banner (e.g. "HP J9298A Switch 2520G-8-PoE") appears on a later line.
Scan all lines and use the first HP/HPE/Aruba banner found.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Guard against show version outputs that start with "Image stamp:" or
other non-banner lines — return ("", "") when the first line doesn't
begin with HP/HPE/Aruba.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
parse_system_info() now extracts HPE/HP J-codes (e.g. J9298A, J9777A)
from the System Model field and returns them as part_number separately.
The model name is cleaned of the J-code and surrounding punctuation:
"HP J9298A Switch 2520G-8-PoE" → model="HP 2520G-8-PoE Switch", pn="J9298A"
"HP2530-8G Switch(J9777A)" → model="HP2530-8G Switch", pn="J9777A"
get_facts() includes part_number in the returned dict so NetOrk can
store it on Device.part_number and pass it to NetBox device types.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>