bmc (napalm_redfish.bmc:BmcDriver) reads a BMC over Redfish where it
answers. A BMC that refuses Redfish (no license) is read and switched over
IPMI. A getter that fails over Redfish is asked over IPMI where IPMI has it;
IPMI is opened only then. Power control goes over Redfish when it answers,
and a refusal is final. The BMC is reset over Redfish only. Same account
for both; ipmi_port in optional_args.

Discovery suggests bmc for a BMC it finds: the fingerprint rules moved from
RedfishDriver to BmcDriver.
2026-10-17 10:34:20 +02:00

4.1 KiB

Getters mapped to Redfish resources

Paths use the usual single-member IDs (Systems/1, Managers/1, Chassis/1); the driver must follow the collections instead of assuming IDs, because vendors differ (Dell uses System.Embedded.1, HPE uses 1, Supermicro uses 1).

Authentication

  • Session: POST /redfish/v1/SessionService/Sessions with user and password returns an X-Auth-Token header and the session's URI. Use the token, DELETE the session on close. BMCs allow few concurrent sessions, so leaking them locks out the web UI.
  • Basic auth works on most services and is the fallback.
  • Self-signed certificates are the norm; verification is configurable per device.

NAPALM getters

Getter Resource Fields
get_facts Systems/{id}, Managers/{id} Manufacturer, Model, SerialNumber, HostName; BMC FirmwareVersion as os_version. uptime is not in Redfish (return -1). interface_list from Managers/{id}/EthernetInterfaces
get_interfaces Managers/{id}/EthernetInterfaces/* BMC ports: MACAddress, SpeedMbps, LinkStatus, InterfaceEnabled
get_interfaces_ip same IPv4Addresses, IPv6Addresses
get_environment Chassis/{id}/Thermal (Temperatures[], Fans[]), Chassis/{id}/Power (PowerSupplies[], PowerControl[].PowerConsumedWatts) Newer services move these to ThermalSubsystem, PowerSubsystem and Sensors; read whichever exists. CPU and memory of the host OS are unknown to a BMC
get_users AccountService/Accounts/* UserName, RoleId, Enabled
get_ntp_servers Managers/{id}/NetworkProtocol NTP.NTPServers (newer schema versions only)
get_snmp_information Managers/{id}/NetworkProtocol SNMP.ProtocolEnabled (details vary)
get_config n/a A BMC has no configuration file. Not implemented

Role methods (draft, see role.md)

Method Resource
get_power_state Systems/{id}: PowerState
set_power_state POST Systems/{id}/Actions/ComputerSystem.Reset with ResetType; allowed values from ResetType@Redfish.AllowableValues (or the ActionInfo resource)
reboot_host (the BMC) POST Managers/{id}/Actions/Manager.Reset
get_hardware_inventory Systems/{id} (ProcessorSummary, MemorySummary), Systems/{id}/Processors/*, Systems/{id}/Memory/*, Systems/{id}/Storage/* (older: SimpleStorage), Chassis/{id}/Power PSUs, Systems/{id}/EthernetInterfaces/*
get_event_log Systems/{id}/LogServices/*/Entries or Managers/{id}/LogServices/*/Entries (where the SEL lives varies by vendor)
get_firmware_inventory UpdateService/FirmwareInventory/*: Name, Version, Updateable
get_management_protocols Managers/{id}/NetworkProtocol: HTTP, HTTPS, SSH, IPMI, SNMP, KVMIP, VirtualMedia, SSDP, each with ProtocolEnabled and Port

IPMI fallback (ipmi entry point)

Via pyghmi: device ID and FRU data for get_facts, sensor data repository for get_environment, chassis status for get_power_state, SEL for get_event_log. set_power_state sends a chassis control (On → power up, GracefulShutdown → soft off via ACPI, ForceOff → power down, ForceRestart → hard reset). IPMI has no graceful restart, and pyghmi offers no power cycle, so get_power_state never offers those two. No BMC reset over IPMI.

Redfish and IPMI together (bmc entry point)

BmcDriver holds a RedfishDriver and an IpmiDriver for the same BMC and account:

Situation Used
Redfish answers Redfish for every getter; IPMI is not opened
A getter fails over Redfish (RedfishError, ConnectionException) that getter over IPMI, if IPMI has it (Redfish-only getters re-raise)
The service root refuses Redfish for want of a license, or Redfish does not answer IPMI for everything; Redfish-only getters raise NotImplementedError
set_power_state Redfish when it answers; a refusal (RuntimeError) is final
reboot_host Redfish only (Manager.Reset)
get_management_protocols over IPMI {"ipmi": {"enabled": True, "port": 623}}