fix: read a Supermicro X10 with only the OOB license over Redfish (0.3.1)
First run against real hardware over Redfish: an X10DRL-i (BMC 3.91) with
SFT-OOB-LIC. Its Redfish tree is recorded under
tests/fixtures/supermicro-x10drl-i-3.91/redfish, scrubbed.
- A resource refused for want of a further license (403 OemLicenseNotPassed)
no longer fails the getter. Storage then falls back to SimpleStorage. The
firmware list falls back to the BMC and BIOS versions when UpdateService
is withheld.
- get_device_warnings reports bmc_license_partial with the licenses and the
withheld parts (drives, firmware inventory).
- A placeholder system model ("Super Server") is replaced by the board
(PartNumber, else the chassis model).
This commit is contained in:
1 parent
6c60f7ac60
commit
adf152ee12
78 files changed
+3237
-24
No files matched your search
+1
-1
@@ -4,7 +4,7 @@ build-backend = "setuptools.build_meta"
|
||||
|
||||
[project]
|
||||
name = "napalm-redfish"
|
||||
version = "0.3.0"
|
||||
version = "0.3.1"
|
||||
description = "NAPALM driver for server baseboard management controllers over DMTF Redfish"
|
||||