feat(time-sync): the box's NTP servers through TimeSyncMixin
netOrk keeps one list of NTP servers per site and aligns a device that
differs (NetOrk/netork#2360). The Fritz!Box takes part through TR-064's
Time:1 service: GetInfo reads NewNTPServer1/2, SetNTPServers writes
them.

AVM documents Time:1's zone fields as not supported, and the box keeps
its zone as a POSIX rule or nothing, so the zone is read as None unless
the box names an IANA zone, and time_sync_writes is {"ntp_servers"}.
The box has two server slots: a longer list is refused before anything
is written, and a list the box already has is not written again, so a
poll that aligns the box every time does not churn.

TR-064 says neither whether the clock is synchronised nor whether the
box serves time to its LAN (NetOrk/netork#2371); both stay unreported.

Needs napalm-device-types 4.35.0.

Refs NetOrk/netork#2367